chemistrery logo

Log in Register

Login to your account

Username *
Password *
Remember Me

Neutral red (C.I. 50040)

(C.I. 50040) for microscopy
Certistain®.
CAS 553-24-2,
pH 3.1 (10 g/l, H₂O, 20 °C).
Code: 1013760025
To display price and insert in cart, please register or login to your account.

(C.I. 50040) for microscopy Certistain®. CAS 553-24-2, pH 3.1 (10 g/l, H₂O, 20 °C).
Description
Catalogue Number 101376
Description NEUTRAL RED (C.I. 50040) FOR MICROSCOPY
Overview NEUTRAL RED (C.I. 50040) is a dry dye of the series of Certistain® dyes that is used for the preparation of a staining solution that can be used for supravital staining of leukocytes in blood of human origin. Further it is applied in histology for nuclear staining, fluorescence staining, polychrome staining or for counter staining in Gram staining. It is a CERTISTAIN® dye that is chemically quality-certified according to highest standards and strict specifications. As an IVD product and CE registered, it can be used hassle-free in diagnostics and laboratory accreditations.
Product Information
CAS number 553-24-2
EC number 209-035-8
Hill Formula C₁₅H₁₇ClN₄
Molar Mass 288.78 g/mol
HS Code 3204 13 00
Structure formula Image
Applications
Application Neutral red (C.I. 50040) for microscopy Certistain®. CAS 553-24-2, pH 3.1 (10 g/l, H₂O, 20 °C). MSDS and product info below.
Physicochemical Information
pH value 3.1 (10 g/l, H₂O, 20 °C)
Bulk density 350 - 500 kg/m3
Solubility 50 g/l
Safety Information according to GHS
Storage class 10 - 13 Other liquids and solids
WGK WGK 2 water endangering
Disposal 3
Relatively unreactive organic reagents should be collected in container A. If halogenated, they should be collected in container B. For solid residues use container C.
Storage and Shipping Information
Storage Store at +5°C to +30°C.
Specifications
Dye content (spectrophotometrically) ≥ 90 %
Identity (UV/VIS-Spectrum) passes test
Absorption maximum λ max (ethanol 50 %) 540 - 543 nm
Spec. Absorptivity A 1%/1cm (λmax; 0.005 g/l; ethanol 50 %) 1420 - 1610
TLC-Test passes test
Loss on drying (110 °C) ≤ 12 %
Suitability for microscopy passes test
 logo new

instagram l   Telegram Messenger